Table 157: Descriptions <strong>and</strong> Recommendations for Error Types 3842-3942 4 of 4<br />

Error<br />

Code<br />

Description Recommendation<br />

3919 Service or option not<br />

implemented,<br />

unspecified. Used<br />

when no other cause in<br />

this class applies.<br />

3928 A call was denied<br />

because of a basic<br />

incompatibility existed<br />

between the type of call<br />

<strong>and</strong> either the facilities<br />

selected by the routing<br />

pattern or the called<br />

user.<br />

3942 Timer expiry: T310<br />

time-out, no answer to<br />

CALL PROCEEDING.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

This <strong>error</strong> might be helpful as a clue if the customer<br />

complains of receiving unexpected intercept tone after<br />

accessing ISDN trunks or PRI endpoints. Determine the<br />

trunk group from the circuit pack or media module <strong>and</strong> port<br />

number (in the Aux Data field) <strong>and</strong> then check the BCC<br />

fields of the pertinent routing patterns. Also, investigate<br />

whether or not the calling <strong>and</strong> called endpoints are<br />

compatible (for example, some ISDN switches may not<br />

allow a voice station to call a data extension).<br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

556 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

Primary Signaling Link Hardware Check (#636) X X ND<br />

Secondary Signaling Link Hardware Check (#639) X X ND<br />

Layer 2 Status Query Test (#647) X X ND<br />

Remote Layer 3 Query (#637) X X ND<br />

1. D = Destructive; ND = Nondestructive<br />