h. Error Type 1025: Processor/Tone-Clock circuit on-board maintenance has detected one or<br />

more clock slips, timing differences between its internal reference source <strong>and</strong> the<br />

synchronization signal provided by the master Tone-Clock. Although no clock slip <strong>error</strong>s are<br />

expected during normal operation, both manual <strong>and</strong> automatic interchanges of Tone-Clock<br />

circuit, synchronization references, <strong>and</strong> PNCs could result in clock slip counts.<br />

If Error Type 1281 also is logged for the same Tone-Clock circuit, it is related to this problem<br />

<strong>and</strong> should be corrected first. Otherwise, continue with the following procedure.<br />

1. Use <strong>test</strong> tone-clock location, <strong>and</strong> examine the results of Test #149 to see if<br />

slip <strong>error</strong>s still appear. If no new slip <strong>error</strong>s are reported, <strong>and</strong> if these <strong>error</strong>s are not<br />

causing a TDM-CLK alarm, they may be ignored. Use <strong>test</strong> tone-clock<br />

location long clear to clear the <strong>error</strong>s.<br />

2. Otherwise, enter display <strong>error</strong>s, <strong>and</strong> follow corrective procedures for any other<br />

TDM-CLK, TONE-BD, SYNC, DS1C-BD, EXP-INTF, SNC-BD, <strong>and</strong> SNI-BD <strong>error</strong>s<br />

logged, except for those in Table 261: Error Log Entries for Slip Errors.<br />

Table 261: Error Log Entries for Slip Errors<br />

Circuit Pack Name Error Log Name Error Log Number of Slips<br />

DS1 Interface DS1-BD 3073 to 3160<br />

Expansion Interface EXP-INTF 2305<br />

Switch Node Interface SNI-BD 1537<br />

Tone-Clock TDM-CLK 1025<br />

UDS1 Interface 3073 to 3160<br />

DS1C Circuit Pack DS1C-BD 3329<br />

3. If Error Type 1025 <strong>error</strong>s persist, see SYNC (Port Network Synchronization).<br />

i. Error Type 1281: the Processor/Tone-Clock circuit has detected a loss of timing signal from<br />

the system’s synchronization reference. The Processor/Tone-Clock circuit has switched<br />

synchronization references.<br />

1. Resolve any <strong>error</strong>s logged against the SYNC (Port Network Synchronization) or<br />

STRAT-3 (Stratum-3 Clock) MOs.<br />

2. See SYNC (Port Network Synchronization), if the <strong>error</strong> is not resolved by step 1.<br />

Error Type 1282: the TN2182 tone-clock was synchronized to a DS1 facility <strong>and</strong> that the<br />

reference frequency provided by the DS1 drifted beyond a range that could be tracked by<br />

the TN2182. Therefore the TN2182 is no longer synchronized to that DS1 reference. If a<br />

second DS1 is available, the tone-clock may be synchronized to that reference. If no<br />

secondary DS1 reference is available, the tone-clock will run off of its internal clock. This<br />

may result in slips being reported by the tone-clock <strong>and</strong> every DS1 facility.<br />

968 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers