Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

For SNC circuit packs, this <strong>test</strong> determines if the circuit pack can communicate with the other<br />

SNC, <strong>and</strong> which SNIs the SNC can talk to over the serial communication chel.<br />

This <strong>test</strong> is run by entering <strong>test</strong> board or <strong>test</strong> board long for SNI or SNC circuit packs,<br />

or <strong>test</strong> fiber-link for fiber links with SNI or EI endpoint(s).<br />

Failures of this <strong>test</strong> cause entries in the <strong>error</strong> <strong>and</strong> alarm logs against Switch Node Configuration<br />

(SN-CONF) with the board location of the SNI or SNC.<br />

For <strong>descriptions</strong> of result <strong>codes</strong> for this <strong>test</strong>, see:<br />

● FIBER-LK Error <strong>codes</strong> <strong>and</strong> recommended actions for fiber links.<br />

● SNC-BD Error <strong>codes</strong> <strong>and</strong> recommended actions when the circuit pack <strong>test</strong>ed is a Switch<br />

Node Clock (circuit pack slots 10 or 12).<br />

● SNI-BD Error <strong>codes</strong> <strong>and</strong> recommended actions when the circuit pack <strong>test</strong>ed is a Switch<br />

Node Interface (circuit pack slots 2–9 or 13–20).<br />

Incorrectly Connected Administered Fibers<br />

Some physically connected fibers that do not match fiber administration can cause port network<br />

problems that are not detected <strong>and</strong> alarmed by this <strong>test</strong>. The symptoms will usually be phone<br />

calls not working correctly, <strong>and</strong> port network component alarms due to translation mismatches.<br />

This <strong>test</strong> is unable to detect the case where an SNI is connected to the same type of board (EI<br />

or SNI) as administered but located in a different cabinet with the same carrier <strong>and</strong> same slot as<br />

the administered fiber endpoint. Enter list fiber-link to view the administered fiber<br />

endpoint. This <strong>test</strong> detects if the fiber endpoint connected to the SNI is in a different carrier <strong>and</strong><br />

slot location than the administered fiber endpoint.<br />

Incorrectly Connected SNI-to-EI Fibers<br />

If the SNI is connected to the same type of fiber endpoint as the administered fiber endpoint, but<br />

the location is the same as administered except for the cabinet, every phone call will work<br />

incorrectly; some phone calls will not go through <strong>and</strong> others will ring the wrong phone.<br />

To check connectivity:<br />

1. Enter <strong>test</strong> led port-network for each administered port network <strong>and</strong> verify that the<br />

LEDs on the correct port network are lit.<br />

2. If the LEDS are not lit, enter list fiber-link. Check that the fiber connections to the<br />

port network are consistent with the administered fibers connections of the port network<br />

that does not light the LEDs as expected.<br />

3. Run <strong>test</strong> led switch-node on each administered switch node carrier <strong>and</strong> verify that<br />

the LEDs on the correct carrier are lit.<br />

4. If they are not, check the connectivity to the switch node carrier that does not light the<br />

LEDs as expected.<br />