d. The server is not acknowledging messages from the DS1 converter circuit pack or the DS1<br />

converter circuit pack does not have a processor route. This pattern indicates a probable<br />

software problem.<br />

In addition to the traditional red, green, <strong>and</strong> amber LEDs, the DS1 converter circuit pack has<br />

four green LEDs that indicate whether a receive signal is present for each DS1 facility.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 118: FIBER-LK Error Log Entries<br />

Error<br />

Type<br />

0 1<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 Any Any Any <strong>test</strong> fiber-link F P<br />

1 (b) any Failure audit (#777) (a) MAJ<br />

MIN<br />

WRN<br />

OFF <strong>test</strong> fiber-link F P<br />

18 (c) 0 busyout fiber F P WRN OFF release fiber F P<br />

257 (d) any Failure audit (#777) (a) MAJ<br />

MIN<br />

WRN<br />

513 (e) any Failure audit (#777) (a) MAJ<br />

MIN<br />

WRN<br />

769 (f) any Failure audit (#777) (a) MAJ<br />

MIN<br />

WRN<br />

1025 (g) any Failure audit (#777) (a) MAJ<br />

MIN<br />

WRN<br />

1281 (h) any Failure audit (#777) (a) MAJ<br />

MIN<br />

WRN<br />

OFF <strong>test</strong> fiber-link F P<br />

OFF <strong>test</strong> fiber-link F P<br />

OFF <strong>test</strong> fiber-link F P<br />

OFF <strong>test</strong> fiber-link F P<br />

OFF <strong>test</strong> fiber-link F P<br />

1. Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong> sequence. Refer to each<br />

appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended procedures.<br />

Notes:<br />

a. The Failure Audit (#777) should be run to confirm whether the <strong>error</strong> still exists.<br />

b. Error Type 1: problem with the control path to the neighbor. See Repair procedures.<br />