ae. Error Type 21700-21764: a spontaneous PNC interchange took place in response to the<br />

occurrence of a major or minor alarm on the B-PNC associated with fault class FC_SNIHW.<br />

This indicates faults on hardware connecting SNIs on different switch nodes. Investigate<br />

any alarms against SN-CONF, SNI-BD, FIBER-LK. The last two digits of the Error Code<br />

indicate the fiber-link number (01-27) of the fiber that reported the alarm. Use list<br />

fiber-link to show the location of the fiber.<br />

af. Error Type 51000: a spontaneous PNC interchange took place upon the expiration of the<br />

anti-thrashing timer.<br />

ag. Error Type 52000: a spontaneous PNC interchange took place upon the unlocking of the<br />

PNCs with the set pnc unlock comm<strong>and</strong>.<br />

ah. Error Type 53000: a spontaneous PNC interchange took place upon the completion of a<br />

global refresh of the st<strong>and</strong>by.<br />

ai. Error Type 60801: a dem<strong>and</strong> interchange was executed with reset pnc interchange.<br />

aj. Error Type 60800: a dem<strong>and</strong> interchange was executed with reset pnc interchange<br />

using the override-<strong>and</strong>-lock option.<br />

772 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers