ADX16A-P (AUDIX Analog Line/Control Link)<br />

CAUTION: Never<br />

MO Name in<br />

Log<br />

Alarm<br />

Level<br />

ADX16A-P (AUDIX Analog Line/Control Link)<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

ADX16A-P MIN <strong>test</strong> port location l AUDIX Analog Line/ Control Link<br />

WRN <strong>test</strong> port location<br />

! CAUTION:<br />

do any of the following without first shutting down AUDIX. Follow the<br />

instructions on the TN566/TN2169 faceplate:<br />

● Remove EMBEDDED AUDIX circuit packs<br />

● Cycle power to a carrier containing EMBEDDED AUDIX circuit packs<br />

● Remove power to a carrier containing EMBEDDED AUDIX circuit packs<br />

The ADX16A-P MO represents a port on a TN566/TN2169 EMBEDDED AUDIX circuit pack that<br />

is operating in control-link (CL) mode.<br />

For circuit-pack-level problems (ADX16A-B or ANL-16-B), see XXX-BD (Common Port Circuit<br />

Pack/Media Module).<br />

For port-level problems with AUDIX operating in digital-port mode, see:<br />

● ADX8D-PT (AUDIX Digital Port)<br />

● ADX16D-P (16-Port AUDIX Digital Port)<br />

The <strong>test</strong>s apply only to switch-side maintenance that <strong>test</strong>s a circuit pack’s components related<br />

to the TDM-bus interface. The AUDIX system has an extensive maintenance strategy that is<br />

described in DEFINITY® AUDIX Maintenance, 585-300-110.<br />

AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction board (MFB) <strong>and</strong><br />

the TN2169 Alarm board (ALB). The 2 boards occupy 5 slots, but only 1 slot is functional as far<br />

as the switch is concerned. The other 4 slots are seen by the switch as “AUDIX-reserved” slots.<br />

In CL mode, the TN566 pack supports up to 16 voice ports. When a call to a station with an<br />

AUDIX login is not answered, AUDIX answers the call using one of the available voice ports.<br />

Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.<br />