Table 400: Maintenance/Test Circuit Pack Query Test (#572) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Maintenance/Test Circuit Pack Query Test (#572)<br />

2077 ABORT The Maintenance/Test Circuit Pack Query located more than one<br />

Maintenance/Test packet bus port in the PN.<br />

This is an internal system <strong>error</strong> <strong>and</strong> should not occur. Escalate the<br />

problem, but also attempt the following work-around steps.<br />

1. Remove every Maintenance/Test circuit pack from the PN.<br />

2. Insert one Maintenance/Test circuit pack. There should not be more<br />

than one in a PN.<br />

3. Re-enter the <strong>test</strong> comm<strong>and</strong>.<br />

2100 ABORT Could not allocate all necessary resources to perform this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2500 ABORT An internal operation failed. The <strong>test</strong> could not be completed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2 of 3<br />