● SMRT = Smart Jack<br />

● LPBK = Loopback<br />

TN464GP/TN2464BP UDS1 Circuit Packs with<br />

Echo Cancellation<br />

The TN464GP <strong>and</strong> TN2464BP UDS1 circuit packs feature an integrated echo canceller. Echo<br />

cancellation is a Software Right-To-Use feature that can be turned on as needed. Echo<br />

cancellation supports chels carrying voice <strong>and</strong> is not intended for chels that support data. The<br />

TN464GP/TN2464BP have the capability to detect modem tone <strong>and</strong> turn off echo cancellation<br />

accordingly for the duration of a data call. Echo cancellation on the TN464GP/TN2464BP is<br />

administrable per chel. The echo cancellation circuitry on a given TN464GP/TN2464BP is<br />

driven by administrable parameters.<br />

The TN464GP/TN2464BP circuit packs are intended for use with ATM, IP, wideb<strong>and</strong>, or other<br />

complex services which are likely to have problems with echo.<br />

Echo cancellation on a TN464GP/TN2464BP is a right-to-use feature that is activated by means<br />

of the License File. Echo cancellation is enabled on the System-Parameters Customer-Options<br />

screen. The Maximum Number of DS1 Boards with Echo Cancellation field on the<br />

System-Parameters Customer-Options screen indicates the number of DS1 boards on which<br />

echo cancellation is activated for a specific customer.<br />

The DS1 Circuit Pack screen for the TN464GP/TN2464BP circuit packs has fields to support<br />

echo cancellation: Echo Cancellation, EC Direction, <strong>and</strong> EC Configuration. The Echo<br />

Cancellation field appears when the Echo Cancellation feature is activated on the<br />

System-Parameters Customer Options screen. The EC Direction <strong>and</strong> EC Configuration fields<br />

appear when the DS1 Echo Cancellation field is enabled.<br />

● EC Direction determines the direction from which echo will be eliminated, ether inward or<br />

outward.<br />

● EC Configuration is the set of parameters used when cancelling echo. This information is<br />

stored in firmware on the UDS1 circuit pack.<br />

Echo cancellation is turned on or off on a per trunk-group basis using change trunk-group.<br />

If the TRUNK GROUP field, DS1 Echo Cancellation is y, echo cancellation is applied to every<br />

TN464GP/TN2464BP trunk member in that trunk group. The echo cancellation parameters<br />

used for a given trunk member are determined by the Echo Cancellation Configuration Number<br />

administered on the DS1 Circuit Pack screen for that specific trunk’s board.<br />

Note: It<br />

Note:<br />

is not necessary to busyout a port or trunk group to change the DS1 Echo<br />

Cancellation field on the Trunk Group screen. However, the modified setting does<br />

not take effect until one of the following occurs:<br />

● Port is busied out/released<br />