DS1 Interface Options<br />

DS1-FAC (DS1 Facility)<br />

Use fiber link administration to set the following DS1 Interface options. Use list fiber-link<br />

to check the number of the fiber link. Execute change fiber-link <strong>and</strong> set the following<br />

fields:<br />

Table 92: DS1 Interface Options administration 1 of 3<br />

Field Description<br />

Facility<br />

Installed<br />

Passes<br />

Far-End Clock<br />

Digital Data<br />

Compatible<br />

y when the facility is installed.<br />

For TN574 DS1 converter boards, facility A must be installed first. Install<br />

Facilities B, C <strong>and</strong> D in any order on any of the four facilities.<br />

For TN1654 DS1 converter boards, facility A must be installed first, then B,<br />

then C or D. This is required because the primary facility can only reside on<br />

facilities A or B.<br />

y when the DS1 facility is used as a clock reference for the receive fiber<br />

signal.<br />

Appears on the Fiber-Link screen for TN574 DS1 converter circuit packs.<br />

On the TN1654 DS1 converter board, none of the facilities can be used as a<br />

clock reference for the receive fiber signal, <strong>and</strong> administration of this field is<br />

not applicable.<br />

DS1 facilities cot be used as system synchronization sources.<br />

y when the DS1 facility is digital data compatible <strong>and</strong> suitable for carrying<br />

packet traffic.<br />

Appears on the Fiber-link screen for TN574 DS1 converter circuit packs. The<br />

TN574 circuit pack allows any of the four facilities to be used as the primary<br />

facility that carries the packet traffic.<br />

The TN1654 DS1 converter board allows packet traffic only on facilities A<br />

<strong>and</strong> B, <strong>and</strong> administration of this field is not applicable.<br />

Bit Rate Select domestic T1 operation or international E1 operation for all facilities in<br />

the TN1654 DS1 converter complex:<br />

● 1.544 Mbps for T1 operation<br />

● 2.048 Mbps for E1 operation<br />

Appears on the fiber-link screen only for TN1654 DS1 converter circuit<br />

packs.<br />

The TN1654 DS1 converter circuit pack is also field configurable for T1 or E1<br />

operation. All four DS1 facilities are configured to either T1 or E1 as a group<br />

via an option switch located on the component side of the circuit pack. An<br />

<strong>error</strong> is logged <strong>and</strong> an alarm is raised if there is a T1/E1 inconsistency<br />

between the administered bit rate <strong>and</strong> the board option switch setting.<br />

1 of 3<br />