. Error Type 10000-10063: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the A-PNC associated with fault class FC_EAL. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (10003 points to port network 4) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

c. Error Type 10100-10163: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the A-PNC associated with fault class FC_INL. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (10003 points to port network 4). Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

d. Error Type 10200-10263: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the A-PNC associated with fault class FC_HW. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (10203 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

e. Error Type 10300-10363: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the A-PNC associated with fault class FC_PER. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (10303 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

f. Error Type 10400-10463: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the A-PNC associated with fault class FC_DS1. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (10403 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

g. Error Type 10500-10563: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the A-PNC associated with fault class FC_BFD. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (10203 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

h. Error Type 10600-10664: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the A-PNC associated with fault class FC_SNIL. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms. The<br />

last two digits of the Error Code indicate the fiber-link number of the fiber that reported the<br />

retired alarm. Use list fiber-link to show the location of the fiber.<br />

i. Error Type 10700-10764: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the A-PNC associated with fault class FC_SNIHW. Use status pnc<br />

to look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

768 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers