2. Reset the board with busyout board location, reset board location, <strong>and</strong><br />

release board location. A reset is required to reload RAM associated with the<br />

TN744’s DSPs. This will take all eight tone detector ports out of service for a few<br />

seconds. Only four of the eight would be out of service due to the alarm. (There are<br />

four tone detectors on each of the two DSPs.) Other than the unlikely potential of<br />

running out of tone detector resources in the switch, there is no other effect when the<br />

board is reset.<br />

3. Test the board (<strong>test</strong> board location long).<br />

4. If the <strong>test</strong> passes, terminate the repair process. If the <strong>test</strong> fails, replace the board.<br />

5. Check to see if the board is duplicated (list cabinet <strong>and</strong> status port-network<br />

on the affected PN).<br />

6. If the board is not duplicated, use <strong>test</strong> tone location long to resolve the <strong>error</strong>.<br />

The long <strong>test</strong> resets the board <strong>and</strong> is required to reload on-board RAM associated with<br />

the DSPs. The effect is that tone detectors are taken out of service momentarily <strong>and</strong><br />

tones are removed from the TDM bus for about 10 seconds. This means no dial pulses<br />

or touch tones during this interval, which probably will not affect calls in progress but<br />

could cause a call origination to abort or cause a user to not get dial tone when going<br />

off-hook.<br />

7. If every <strong>test</strong> passes <strong>and</strong> the alarm does not resolve, re<strong>test</strong> (<strong>test</strong> tone location<br />

long clear).<br />

8. If the <strong>test</strong> passes, terminate the repair process. If it fails, replace the circuit pack at the<br />

customer’s convenience.<br />

9. If the board is duplicated, switch to the st<strong>and</strong>by side (set tone/set<br />

ipserver-interface).<br />

10. Test the alarmed board (<strong>test</strong> tone location long). This resets the board <strong>and</strong> is<br />

required to reload on-board RAM associated with the circuit pack’s DSPs.<br />

11. If every <strong>test</strong> passes <strong>and</strong> the alarm does not resolve, re<strong>test</strong> with <strong>test</strong> tone<br />

location long clear.<br />

12. If the <strong>test</strong> passes, terminate the repair process. If it fails, replace the board.<br />

b. Error Type 257: The ETR-PT lost its translation. Testing the ETR-PT is sufficient to reload<br />

its translation. If <strong>test</strong>ing the ETR port does not clear the <strong>error</strong>, the circuit pack containing the<br />

defective ETR port should be replaced at a time when it is convenient to remove a clock<br />

board from the system. Follow the procedures described in TONE-BD (Tone-Clock Circuit<br />

Pack) for replacing a Tone-Clock circuit pack.<br />

c. Error Type 513: This <strong>error</strong> indicates the (ETR-PT) Enhanced Tone Receiver is having<br />

problems detecting touch tones, call-progress tones, or MFC tones. If this Error Type is<br />

persistently logged, the circuit pack containing the defective ETR-PT should be replaced at<br />

a time it is convenient to remove a clock board from the system. Follow the procedures<br />

described in TONE-BD (Tone-Clock Circuit Pack) for replacing a Tone-Clock circuit pack.<br />

424 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers