Error log entries <strong>and</strong> recommended actions<br />

Table 110: EXP-PN Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated<br />

Test<br />

Alarm<br />

Level<br />

On/Off<br />

Board<br />

1 (a) 0 None None<br />

257 (b) 0 None None<br />

513 (c) 0 None MAJ OFF<br />

769 (d) 0 None MAJ OFF<br />

1025 (e) Any None MAJ OFF<br />

EXP-PN (Expansion Port Network)<br />

Recommended<br />

Action<br />

Notes:<br />

a. Error Type 1: informational entry only, indicating that a PN Reset Level 1 (PN Warm<br />

Restart) has been executed on this PN.<br />

b. Error Type 257: informational entry only, indicating that a PN Reset Level 2 (PN Cold<br />

Restart) has been executed on this PN. This does not include restarts done at system<br />

initialization time.<br />

c. Error Type 513: indicates that a PN is not in service when it is expected to be. The value<br />

specified in the port field of the <strong>error</strong> log, is the PN number of the affected PN. When this<br />

condition occurs, examine every system link <strong>error</strong> <strong>and</strong> EXP-INTF or ATM-PNC <strong>error</strong> to aid<br />

in resolving the alarm (examples of system link <strong>error</strong>s are <strong>error</strong>s logged against PKT-INTF,<br />

EXP-INTF, SNI-BD, FIBER-LK, <strong>and</strong> PKT-BUS <strong>and</strong> for ATM, PKT-BUS, ATM-EI,<br />

ATM-NTWK). Also check that all fiber connectivity matches that have been administered for<br />

the system. This alarm <strong>and</strong> <strong>error</strong> is resolved <strong>and</strong> removed from the logs only when the PN<br />

comes back into service.<br />

d. Error Type 769: This alarm is raised when PN maintenance has attempted to execute a<br />

Cold Restart recovery action two times, <strong>and</strong> both restarts failed. This will cause the PN to be<br />

placed in Emergency Transfer. Examine every EXP-INTF or ATM-EI <strong>error</strong> that, when<br />

cleared, may aid in resolving this alarm. Also check for any SNI-BD, SNI-PEER, FIBR-LK,<br />

SN-CONF, or DS1C-BD <strong>error</strong>s or for ATM, ATM-EI or ATM-NTWK <strong>error</strong>s that may indicate a<br />

communication problem between the processor <strong>and</strong> the PN. Make sure that the physical<br />

fiber connectivity matches that of system administration.<br />

e. Error Type 1025: If two cabinets are DS1-C connected <strong>and</strong> their comp<strong>and</strong>ing modes differ,<br />

the system raises a major alarm only if the Multinational Locations field is y on the<br />

Customer Options form. See Administering <strong>Avaya</strong> Aura Communication Manager<br />

(03-300509) for more information about administering multiple locations, particularly the<br />

Locations form in Screen Reference section.<br />

Issue 5 May 2009 453