Table 391: DS1 OPS Switchhook Inquiry Test (#312) 3 of 3<br />

Error<br />

Code<br />

2012<br />

2100<br />

Test<br />

Result<br />

DS1 CO Trunk Dial Tone Seizure Test (#314)<br />

DS1 CO Trunk Dial Tone Seizure Test (#314)<br />

ABORT The <strong>test</strong> was aborted due to a system <strong>error</strong>.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 FAIL Internal system <strong>error</strong>.<br />

1. Look for DS1-BD <strong>and</strong> UDS1-BD <strong>error</strong>s in the Error Log. If there<br />

<strong>error</strong>s are present, see DS1-BD (DS1 Interface Circuit Pack) <strong>and</strong>/<br />

or UDS1-BD (UDS1 Interface Circuit Pack).<br />

2. If a chel multiplexer is used as the remote DS1 endpoint to which<br />

the station connects, refer to the multiplexer vendor’s<br />

maintenance document for diagnosis.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

PASS The station hook states in both switch software <strong>and</strong> DS1 Interface circuit<br />

pack are consistent.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the recommended procedures.<br />

3 of 3<br />

This <strong>test</strong> checks the trunk’s signaling capability provided by the DS1 Interface circuit pack. The<br />

<strong>test</strong> sends a “seizure” message to the DS1 Interface circuit pack <strong>and</strong> expects an “active” reply in<br />

return. The <strong>test</strong> passes if the “active” message is received. It aborts if no message is received. It<br />

fails if the DS1 Interface circuit pack returns a “reorder” message.<br />

This <strong>test</strong> cot be run on a trunk in any of the following conditions:<br />

1. The trunk direction is administered as an incoming only trunk.<br />

2. The trunk has been seized by a normal trunk call.<br />

3. The trunk is administered with maintenance <strong>test</strong> disabled.<br />

4. The trunk is on a port of a DS1 Media Module.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● CO-DS1 (DS1 CO Trunk)<br />

Issue 5 May 2009 1353