Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 336: DS1 Tie Trunk Seizure Test (#136) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2053 ABORT<br />

FAIL<br />

At least one of the following <strong>error</strong>s is found in the Error Log for the DS1<br />

circuit pack or media module:<br />

● 1281 – Loss of Signal<br />

● 1793 – Blue alarm<br />

● 2049 – Red alarm<br />

● 2305 – Yellow alarm<br />

● 1537 – Hyperactivity.<br />

1. Look for the above Error Types in the Error Log <strong>and</strong> follow the<br />

procedures for DS1-BD (DS1 Interface Circuit Pack), UDS1-BD<br />

(UDS1 Interface Circuit Pack), or MG-DS1 (DS1 Interface Media<br />

Module) for the listed Error Types.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The far-end trunk did not respond to the seizure of the near-end trunk<br />

within the allowed time.<br />

1. If the affected port is located on a Media Module, replace the Media<br />

Module.<br />

2. Enter list configuration board location. If the circuit pack<br />

is a TN767B vintage 8 or 9, replace the circuit pack with a TN767C<br />

V3 or later.<br />

3. Verify that the Trunk Type field on the Trunk Group administration<br />

form matches the trunk type administered on far-end switch.<br />

4. Look for DS1-BD, UDS1-BD, or MG-DS1 <strong>error</strong>s in the <strong>error</strong> log. If<br />

any are present, see DS1-BD (DS1 Interface Circuit Pack),<br />

UDS1-BD (UDS1 Interface Circuit Pack), or MG-DS1 (DS1 Interface<br />

Media Module) for repair procedures.<br />

5. Retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

PASS The trunk can be seized for an outgoing call.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />

1236 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

3 of 3