Expansion Interface Control Chel Test (#316)<br />

If the circuit pack is a st<strong>and</strong>by ATM-EI or EI (amber LED off), this <strong>test</strong> queries the circuit pack for<br />

its type <strong>and</strong> vintage information. This <strong>test</strong> runs on ATM-EI (Expansion Interface Circuit Pack)<br />

<strong>and</strong> EXP-INTF (Expansion Interface Circuit Pack).<br />

Table 393: Expansion Interface Control Chel Test (#316) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1030 ABORT The <strong>test</strong> is not being executed on the active PE in a duplex system.<br />

1335 ABORT The PKTINT is on the st<strong>and</strong>by SPE<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

FAIL The ATM circuit pack responded incorrectly, or a PN’s active ATM-EI or<br />

EI circuit pack could not communicate with the PN’s circuit packs.<br />

1. If the PN’s active ATM-EI or EI circuit pack is failing <strong>and</strong> duplicated<br />

PNC is enabled:<br />

a. Enter reset PNC interchange to switch to the st<strong>and</strong>by<br />

PNC.<br />

b. Repeat the short <strong>test</strong> sequence.<br />

c. If <strong>test</strong> continues to fail, enter reset board location to<br />

reset the circuit pack.<br />

2. If the PN’s unduplicated ATM-EI or EI circuit pack is failing:<br />

a. Enter display <strong>error</strong>s <strong>and</strong> display alarms, <strong>and</strong> follow<br />

the associated repair procedures for TDM-CLK (TDM Bus<br />

Clock), TONE-BD (Tone-Clock Circuit Pack), or SYNC (Port<br />

Network Synchronization) alarms/<strong>error</strong>s.<br />

b. Repeat the short <strong>test</strong> sequence.<br />

c. If <strong>test</strong> continues to fail, replace the circuit pack or transceiver.<br />