Table 179: MET-LINE Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

1 (b) 40987<br />

MET-LINE (MET Line)<br />

18 (c) 0 busyout port<br />

location<br />

WRN OFF release port location<br />

130 (d) WRN ON <strong>test</strong> port location<br />

257 (e) 40988 MIN<br />

1<br />

WRN<br />

OFF<br />

513 (f) 40965 Analog Line<br />

Audits (#61)<br />

WRN OFF <strong>test</strong> port location r 4<br />

769 Port Diagnostic<br />

Test (#35)<br />

1025 Hybrid <strong>and</strong> Conf.<br />

Circuits (#57)<br />

1537 (g) 40968 MIN OFF<br />

WRN1 1793 NPE Crosstalk<br />

Test (#6)<br />

2049 (h) 32770<br />

2049 (h) 40967<br />

3840 (i) 40989<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

MIN ON <strong>test</strong> port location l r 3<br />

1 WRN<br />

MIN ON <strong>test</strong> port location l r 3<br />

1<br />

WRN<br />

MIN ON <strong>test</strong> port location l r 3<br />

1<br />

WRN<br />

1. Major or Minor alarms MO can be downgraded to Warning based on the values in set options.<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description <strong>and</strong> follow its procedures.<br />

2 of 2<br />

b. Error Type 1: the data link between the port <strong>and</strong> the terminal is not operational (that is, the<br />

port circuitry has detected an off-board problem). Verify that the MET set is connected <strong>and</strong><br />

that the EPF (Electronic Power Feed) <strong>test</strong> passes. If data transmission problems are<br />

experienced, check for defective wiring or a defective voice terminal, or move terminal<br />

electrically closer to the switch (that is, reduce the length of the wiring between the terminal<br />

<strong>and</strong> the switch). If the problem persists, replace the circuit pack. Once the problem is<br />

resolved, the system retires the alarm after a predetermined time delay.<br />

c. Error Type 18: is logged when maintenance personnel busyout the port. The port is<br />

released from busyout using release port location.<br />

Issue 5 May 2009 623