Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 334: OLS/Power Unit Query Test (#127) 5 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

FAIL<br />

(cont’d)<br />

Description / Recommendation<br />

Internal Looparound Test (#135)<br />

a. If the recycle passes, the port carrier power supplies are<br />

healthy <strong>and</strong> the problem is with one of the circuit packs.<br />

Reinsert the circuit packs one at a time. If the status LED<br />

shows red after reinserting a circuit pack, replace the<br />

defective circuit pack. If the status LED still shows red,<br />

remove the amphenol connector on the back of the slot<br />

containing this circuit pack <strong>and</strong> enter recycle carrier. If<br />

the status LED shows green, the problem is with one of the<br />

telephones or the wiring to one of the telephones on this slot.<br />

b. If either port carrier power supply still shows a red status<br />

LED, check for bent pins <strong>and</strong> cable placement in the affected<br />

carrier. There are failures that can occur on the PN’s<br />

Maintenance circuit pack that will not be detected by their<br />

respective maintenance, but that will cause many, if not<br />

every, environment <strong>test</strong> to fail. If many environment <strong>test</strong>s are<br />

failing, replace the suspect circuit pack, depending on the<br />

system configuration, <strong>and</strong> the <strong>test</strong> rerun.<br />

PASS Both OLSs or power supplies in the <strong>test</strong>ed carrier were found to be healthy<br />

by the PN’s Maintenance circuit pack. If the status LEDs on both OLSs or<br />

power supplies are not showing green, the PN’s MAINT circuit pack may<br />

have incorrectly reported the state of the OLSs. Resolve any alarms on<br />

these MOs.<br />

This <strong>test</strong> is destructive.<br />

The Internal Looparound Test loops the transmitted DS1 bit stream back into the board receiver.<br />

The loop occurs just before the DS1 facility interface. The <strong>test</strong> is highly destructive <strong>and</strong> can only<br />

be initiated by a reset board location comm<strong>and</strong>.<br />

All of the trunks on the DS1 or UDS1 Interface circuit pack must first be busied out using the<br />

busyout board location comm<strong>and</strong> before the Internal Looparound Test can be executed.<br />

The <strong>test</strong> uses the Tone Generator <strong>and</strong> Tone Detector to exercise a bit pattern consistency <strong>test</strong><br />

for all ports. If the transmitted <strong>and</strong> received bit patterns on a trunk are different, the <strong>test</strong> fails.<br />

All trunks of the DS1 Interface circuit pack are restored to the in-service state after<br />

release board location is entered<br />

1230 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />