Error log entries <strong>and</strong> recommended actions<br />

Table 205: PE-BCHL Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> port location<br />

1 (b) Any <strong>test</strong> port location<br />

15 (c) Any Port Audit <strong>and</strong> Update<br />

<strong>test</strong> (#36)<br />

18 (d) 0 busyout<br />

pri-endpoint<br />

extension<br />

busyout port<br />

location<br />

release pri-endpoint<br />

extension<br />

release port location<br />

129 (e) WRN OFF <strong>test</strong> port location<br />

130 (f) WRN ON <strong>test</strong> port location<br />

257 (g) Any <strong>test</strong> port location<br />

513 (h) Any WRN OFF <strong>test</strong> port location<br />

769 (g) Any <strong>test</strong> port location<br />

1281 (i) Any Conference Circuit<br />

Test (#7)<br />

MIN ON <strong>test</strong> port location l r 4<br />

1537 (j) Any NPE Crosstalk Test<br />

(#6)<br />

MIN ON <strong>test</strong> port location l r 3<br />

1793 (k) Any <strong>test</strong> port location<br />

3073 (l) Any Service State audit<br />

(#256)<br />

3585 (m) Any<br />

<strong>test</strong> port location r 2<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description <strong>and</strong> follow its procedures.<br />

b. Error Type 1: disagreement between this switch <strong>and</strong> the terminal adapter at the other end<br />

of the connection with regard to the ISDN call state of the PRI endpoint port. This switch will<br />

714 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers