Table 273: UDS1-BD Error Log Entries 5 of 5<br />

Error<br />

Type<br />

Aux<br />

Data<br />

3999 (af) Any None<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

1. Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong> sequence. Refer to the appropriate<br />

<strong>test</strong>’s description, <strong>and</strong> follow its recommended procedures.<br />

2. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the circuit<br />

pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been missing for a period<br />

of 15 minutes. Warning alarms are also raised against any ports administered on the circuit pack.<br />

3. Minor alarms on this MO may be downgraded to Warning based on values on the set options screen.<br />

4. Major alarms on this MO may be downgraded to minor or warning alarms based on values set on the set<br />

options screen.<br />

Notes:<br />

a. Error Type 1: indicates that the circuit pack has stopped functioning or is not fully<br />

administered. The alarm is logged about 15 minutes after the circuit pack has been<br />

removed or 11 minutes after the SAKI <strong>test</strong> (#53) fails.<br />

To be fully administered, a UDS1 circuit pack must meet all of the following conditions:<br />

● Have an entry in the circuit plan using change circuit-pack<br />

● Be administered using add ds1 location<br />

Recommended Action<br />

● Be physically inserted into the correct slot<br />

If the circuit pack has an entry in the circuit plan <strong>and</strong> either of the other conditions are not<br />

met, a MINOR alarm is logged. To resolve the <strong>error</strong>:<br />

1. Make sure that all conditions for administration are met <strong>and</strong> that a functioning UDS1<br />

circuit pack is inserted in the correct slot.<br />

or<br />

2. Completely remove the UDS1-BD from the system:<br />

a. Remove any administered DS1 trunks, access endpoints or PRI endpoints<br />

associated with the circuit pack from their trunk groups.<br />

b. Execute remove ds1 location <strong>and</strong> change circuit-pack location.<br />

If every administration condition is met for this circuit pack <strong>and</strong> the red LED is still on,<br />

follow the instructions for LED alarms without Alarm Log entry or with Error Type 1 in LED<br />

Descriptions for <strong>Avaya</strong> Aura Communication Manager Hardware Components<br />

(03-602804)<br />

b. Error Type 18: the UDS1 Interface circuit pack was busied out by busyout board<br />

location.<br />

1032 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />