Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

This <strong>test</strong> checks the on-board transmission capabilities of the NPE, the codec, <strong>and</strong> the battery<br />

feed chip of the analog port. A Tone Detector <strong>and</strong> a Tone Generator talk <strong>and</strong> listen on the same<br />

pair of time slots as the analog port. The analog port is then instructed to go into looparound<br />

mode (see Figure 96: Looparound <strong>and</strong> Conference Test). The <strong>test</strong> passes if the signal<br />

measured by the Tone Detector is within acceptable limits.<br />

The Conference Circuit <strong>test</strong> verifies that the NPE chel for the port being <strong>test</strong>ed can correctly<br />

perform the conferencing function. Test #47 also <strong>test</strong>s the operation of the port conference<br />

circuits in the NPE for three <strong>and</strong> four parties. In addition, a <strong>test</strong> is run to measure noise. The<br />

NPE is instructed to listen to several different tones <strong>and</strong> conference the tones together. The<br />

resulting signal is then measured by a Tone Detector port. If the level of the tone is within a<br />

certain range, the <strong>test</strong> passes.<br />

The noise <strong>test</strong> is performed by filtering out the tone <strong>and</strong> measuring inherent port noise.<br />

Problems with the port can cause noisy or unreliable connections, or users may report hearing<br />

an echo.<br />

Note: This<br />

Note:<br />

looparound <strong>test</strong> is sensitive to the length of the loop, the equipment in the<br />

loop, or the equipment terminating the loop, such as off-premises stations. If this<br />

<strong>test</strong> is causing a false alarm, use change station for this station <strong>and</strong> change<br />

the Tests field to n to disable the <strong>test</strong>.<br />

Figure 96: Looparound <strong>and</strong> Conference Test<br />

BFC: Battery Feed Chip<br />

NPE: Network Processing Element<br />

Tone<br />

Detector<br />

Tone<br />

Generator<br />

TDM BUS<br />

Analog<br />

Line<br />

Port<br />

1146 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

BFC<br />

CODEC<br />

NPE