Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 467: PN Warm Restart Test (#956) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL Internal system <strong>error</strong><br />

1. Retry the reset comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

PASS The PN Warm Restart procedure completed successfully.<br />

Analog Port Sanity Test (#963)<br />

This <strong>test</strong> verifies that the port circuitry involved in the analog trunk <strong>test</strong>ing on the Maintenance/<br />

Test analog port is functioning properly.<br />

This <strong>test</strong> will abort if an ATMS <strong>test</strong> call is in progress on the Maintenance/Test analog port when<br />

the <strong>test</strong> is requested.<br />

This <strong>test</strong> runs on M/T-ANL (Maintenance/Test Analog Port).<br />

Table 468: Analog Port Sanity Test (#963)<br />

Error<br />

Code<br />

2000<br />

2100<br />

2500<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

System resources required to run this <strong>test</strong> are not available.<br />

An internal operation failed. The <strong>test</strong> could not be completed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

50 FAIL The switch was unable to communicate with the port circuitry used for<br />

analog trunk <strong>test</strong>ing.<br />

1. Reset the circuit pack.<br />

2. Test the port again using <strong>test</strong> port location l.<br />

3. If the <strong>test</strong> fails again, replace the circuit pack.<br />

PASS The Maintenance/Test analog port analog trunk <strong>test</strong>ing capability is<br />

operating correctly.<br />