Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 454: Far-End Internal Loopback Test (#797) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2300 ABORT The downlink message necessary to run this <strong>test</strong> could not be sent.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2301 ABORT The timer could not be set before sending the downlink message.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2316 ABORT Fiber link is not administered.<br />

1. Enter add fiber-link to administer the DS1 converter.<br />

2321 ABORT DS1 facility is not busied out.<br />

1. Enter busyout ds1-facility to busyout the DS1 facility.<br />

2. If there is only one DS1 facility, use busyout board to busyout<br />

the DS1 converter circuit pack.<br />

2332 ABORT For this system configuration, the <strong>test</strong> cot run at the far end when there is<br />

only one DS1 facility available.<br />

1. Run the <strong>test</strong> at the other end of the DS1 converter complex.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1514 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />