Communication Manager Maintenance Object Repair Procedures<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 27: ASAI-PT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated<br />

Test<br />

Alarm Level On/Off<br />

Board<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 1: Level 1 Status inquiry failed or the BRI circuit pack detected that Level 1 has<br />

been deactivated on the port. The Aux Data field contains one of the following values:<br />

Refer to the repair procedures for Level 1 Status Inquiry Test (#621) If the alarm does not<br />

clear, verify the status of the PC/server. This could be a customer network issue <strong>and</strong> not a<br />

board problem.<br />

c. Error Type 513: The circuit pack is having problems transmitting data to the packet bus.<br />

This <strong>error</strong> occurs when the packet bus transmit FIFO buffer overflows <strong>and</strong> most likely<br />

indicates a hardware problem. Use troubleshooting procedures for both on-board hardware<br />

problems <strong>and</strong> potential off-board packet bus problems.<br />

112 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> port location<br />

1 (b) (a) Level 1 Status<br />

Inquiry (#621)<br />

OFF <strong>test</strong> port location r 2<br />

513 (c) 0 none MAJ ON<br />

1537 (d) 46210 CRC Error<br />

Counter (#623)<br />

3841 (e) 46208 None<br />

3844 (f) 46223 None<br />

3845 (g) 46211 None<br />

3846 (h) TEI None<br />

MAJ 1<br />

MAJ1 OFF<br />

1. Major <strong>and</strong> Minor alarms may be downgraded to warning alarms based on the value used in set options.<br />

Blank The Level 1 Status Inquiry failed.<br />

32773 The ASAI-Line circuit pack detected Level 1 has been deactivated.