Modem Pool Conversion Resource Looparound Test (#98)<br />

Table 321: Modem Pool Conversion Resource Looparound Test (#98) 2 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1340 ABORT No Maintenance/Test digital port is currently available for this <strong>test</strong>.<br />

1. Enter list config <strong>and</strong> check if the Maintenance/Test digital<br />

ports (ports 02 <strong>and</strong> 03) are present in the system. If the ports are<br />

displayed, proceed to step 2. Otherwise, see M/T-PKT<br />

(Maintenance/Test Packet Bus Port) <strong>and</strong> M/T-DIG (Maintenance/<br />

Test Digital Port) to determine why no ports appear in the list<br />

config display.<br />

2. Look for M/T-DIG <strong>error</strong>s in the <strong>error</strong> log. If present, refer to M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

3. If the ports are present <strong>and</strong> no <strong>error</strong>s are logged against them, retry<br />

the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

4. If the <strong>test</strong> continues to abort, replace the Maintenance/Test circuit<br />

pack.<br />

5. If the <strong>test</strong> continues to abort after replacement, escalate the<br />

problem.<br />

2004 ABORT Off-hook was not received from the Pooled Modem.<br />

1. Busyout the digital port being <strong>test</strong>ed on the Pooled Modem circuit<br />

pack.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

3. If the <strong>test</strong> still aborts, replace the circuit pack.<br />

4. If the <strong>test</strong> continues to abort after replacement, escalate the<br />

problem.<br />

2005 ABORT The Maintenance/Test <strong>and</strong> the Pooled Modem boards’ digital ports failed<br />

to h<strong>and</strong>shake.<br />

1. Look for M/T-DIG <strong>error</strong>s in the <strong>error</strong> log. If any are present, refer to<br />

M/T-DIG (Maintenance/Test Digital Port)<br />

2. If no <strong>error</strong>s are present retry the comm<strong>and</strong> at 1-minute intervals up<br />

to 5 times.<br />

3. If the <strong>test</strong> still aborts, replace the Pooled Modem circuit pack.<br />

4. If the <strong>test</strong> continues to abort after replacement, escalate the<br />

problem.<br />

2 of 5<br />