Table 359: Data Module Internal Looparound Test (#175) 2 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Data Module Internal Looparound Test (#175)<br />

1005 ABORT Looparound <strong>test</strong>ing is not enabled on the data module administration<br />

screen.<br />

1. Set Looparound Test field to y on the data module administration<br />

screen.<br />

2. Retry the <strong>test</strong>.<br />

1340 ABORT No Maintenance/Test digital port is currently available to perform this <strong>test</strong>.<br />

1. Enter list config to determine whether the Maintenance/Test<br />

digital ports 02 <strong>and</strong> 03 are present in the system. Because at least<br />

one Maintenance/Test circuit pack must always be present in the PN<br />

of S8700 configurations, there should be at least two such ports<br />

present. If the ports are present, proceed to step 2. Otherwise,<br />

determine why no ports appear in the list config display. See<br />

M/T-DIG (Maintenance/Test Digital Port) <strong>and</strong> M/T-BD (Maintenance/<br />

Test Circuit Pack).<br />

2. Look for M/T-DIG <strong>error</strong>s in the Error Log. If present, see M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

3. If the ports are present <strong>and</strong> no <strong>error</strong>s are logged against them, retry<br />

the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

4. If the <strong>test</strong> continues to abort, replace the Maintenance/Test circuit<br />

pack.<br />

1341 ABORT No time-slots available to connect digital ports for the <strong>test</strong>.<br />

1. Try the comm<strong>and</strong> again at 1-minute intervals up to 5 times.<br />

1342 ABORT Connection failed.<br />

1. Try the comm<strong>and</strong> again at 1-minute intervals up to 5 times.<br />

1392 ABORT This port is a TTI port. The <strong>test</strong> does not run on TTI ports.<br />

1. Verify that the port is a TTI port using display port where the<br />

display shows that the port is a TTI port, or list config, where<br />

the display shows a t for the port.<br />

2. If list config or display port indicate that the port is not a<br />

TTI port, escalate the problem. If both comm<strong>and</strong>s indicate that the<br />

port is a TTI port, no action is necessary.<br />