Table 477: TSI Looparound Test (#1108) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

TSI Looparound Test (#1108)<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service due<br />

to TDM-BUS <strong>error</strong>s. A system is considered under heavy traffic when the<br />

Call Processing Occupancy is greater than 50% or when the System<br />

Management <strong>and</strong> the Call Processing Occupancies together exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> resolve any TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a tone receiver for the <strong>test</strong>. The system may<br />

be oversized for the number of Tone Detectors present, or some Tone<br />

Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see information<br />

regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) <strong>error</strong>s.<br />

3. Resolve any TONE-PT (Tone Generator) <strong>error</strong>s.<br />

4. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. If this result occurs repeatedly, attempt to reset the circuit pack if the<br />

other ports are idle.<br />

2. Rerun the <strong>test</strong>. If this result occurs again, replace the circuit pack.<br />

2012 ABORT Internal system <strong>error</strong>. This is an abnormal abort.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The TSI was found to be transmitting in <strong>error</strong>, causing noisy <strong>and</strong> unreliable<br />

connections.<br />

1. Replace the circuit pack.<br />

PASS The TSI is correctly using its allocated time slots.<br />

2 of 2<br />