Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

This <strong>test</strong> runs on SNI-BD (SNI Circuit Pack) <strong>and</strong> SNI-PEER (SNI Peer Link).<br />

Table 443: Packet Neighbor Link Test (#767) 1 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2300 ABORT The downlink message necessary to run this <strong>test</strong> could not be sent.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2301 ABORT The software timer could not be set before sending the downlink message<br />

necessary to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2302 ABORT Software received incorrect message data from the SNI circuit pack.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2303 ABORT The SNI circuit pack responded that the software <strong>test</strong> requested is invalid.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2304 ABORT SNI firmware is not able to run the <strong>test</strong>. For this particular <strong>test</strong>, the SNI<br />

circuit pack must be able to communicate with its neighbor.<br />

1. Verify that the SNI can communicate with its neighbor by checking<br />

the yellow LED of the SNI to make sure the SNI is in frame, or by<br />

running <strong>test</strong> board for the SNI <strong>and</strong> checking <strong>test</strong> 989 for fiber<br />

out-of-frame. If the results of Test 989 indicate that the fiber is<br />

out-of-frame, follow the recommendation associated with the <strong>test</strong><br />

failure. If a DS1 converter complex exists on the fiber link, enter<br />

display <strong>error</strong>s <strong>and</strong> follow the repair procedures for any<br />

DS1C-BD <strong>and</strong> DS1-FAC entries.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1484 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />