Table 323: Sanity H<strong>and</strong>shake Test (#106) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Sanity H<strong>and</strong>shake Test (#106)<br />

FAIL No response to the Sanity H<strong>and</strong>shake.<br />

1. Verify that the carrier A power units are good. If the -5 Volt unit is<br />

defective in the A carrier, communication with the PN’s<br />

Maintenance circuit pack will not be possible.<br />

2. If the -5 Volt unit is good <strong>and</strong> this <strong>test</strong> fails continuously, the<br />

system will automatically run the PN’s Maintenance Circuit Pack<br />

Reset <strong>test</strong> (#306). Otherwise, manually reset a PN’s<br />

Maintenance circuit pack by entering <strong>test</strong> maintenance<br />

long <strong>and</strong> evaluate any Error Codes from PN Maintenance<br />

Circuit Pack Reset Test (#306). If Test #306 passes, this <strong>test</strong><br />

should also PASS. Use the following steps to determine whether<br />

the PN’s Maintenance circuit pack or its serial link is defective:<br />

Duplicated Port Network Connectivity (PNC):<br />

1. Switch PNC by entering reset pnc interchange.<br />

2. Run the short <strong>test</strong> sequence against the PN’s Maintenance<br />

circuit pack. If Test #106 still fails, replace the Maintenance<br />

circuit pack <strong>and</strong> re<strong>test</strong>. Otherwise, follow the procedures for any<br />

<strong>error</strong>s that are logged by this <strong>test</strong>.<br />

Unduplicated PNC:<br />

1. Replace the PN’s Maintenance circuit pack <strong>and</strong> run the short<br />

<strong>test</strong> sequence against it.<br />

2. If the <strong>error</strong> persists, replace the PN Expansion Interface circuit<br />

pack, at a time when the PN can go down with minimal<br />

inconvenience.<br />

3. If the <strong>error</strong> still persists, the problem is with the actual serial link<br />

in the A carrier backplane <strong>and</strong> not with the PN’s Maintenance<br />

circuit pack.<br />

PASS The communication path to <strong>and</strong> from the PN’s Maintenance circuit<br />

pack is sane, <strong>and</strong> the Maintenance circuit pack can read <strong>and</strong> report the<br />

correct PN cabinet type. The Maintenance circuit pack may still have<br />

problems related to Tests #228, #229, #303, or #306.<br />

2 of 2<br />

Issue 5 May 2009 1203