Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 402: Board Type Check Test (#574)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore<br />

2012 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

ANY FAIL Stratum-3 clock synchronization is administered for the carrier where this<br />

Tone-Clock circuit pack resides, but the Tone-Clock does not have board<br />

code TN780.<br />

1. If the Stratum-3 clock option is incorrectly administered, change it.<br />

2. Otherwise, replace the circuit pack. See Replacing the IPSI or<br />

Tone-Clock Circuit Pack.<br />

PASS The proper Tone-Clock circuit pack is present for Stratum-3 clock<br />

synchronization.<br />

Expansion Interface Packet Interface Test (#589)<br />

This <strong>test</strong> attempts to send a data packet from the TN1655 Packet Interface circuit pack through<br />

any intervening EI circuit packs <strong>and</strong>/or SNI circuit packs <strong>and</strong> through the EI circuit pack to be<br />

<strong>test</strong>ed. The path the data packet takes is dependent on the location of the EI circuit pack to be<br />

<strong>test</strong>ed <strong>and</strong> whether the system has duplicated PNC. The following diagrams <strong>and</strong> short<br />

discussion of each describe the different paths the <strong>test</strong> uses.<br />

Figure 102: Expansion Interface Packet Interface Test—Packet Endpoint Loop<br />

PKT-<br />

INT<br />

Packet Bus (PPN) Packet Bus (PN X)<br />

EXP-INTF EXP-INTF<br />

(Optional)<br />

The path shown in Figure 102: Expansion Interface Packet Interface Test—Packet Endpoint<br />

Loop is used when <strong>test</strong>ing a PN EI that is on the active PNC.<br />

1374 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

CSS<br />

LAPD<br />

ENDPT