Table 165: MAINT Error Log Entries 2 of 2<br />

Error<br />

Type<br />

513 (b) 0<br />

1<br />

MGR I Channel Loop<br />

<strong>test</strong> (#228)<br />

769 (c) Any Sanity H<strong>and</strong>shake <strong>test</strong><br />

(#106)<br />

1537 (d) 0<br />

1<br />

Sanity Maze <strong>test</strong><br />

(#303)<br />

2049 (d) Any Battery Holdover<br />

Vintage Verification<br />

Test (#311)<br />

2561 (b) 0<br />

1<br />

Aux<br />

Data<br />

2817 (b) 0 (c)<br />

1<br />

Associated Test Alarm<br />

Level<br />

Sanity H<strong>and</strong>shake <strong>test</strong><br />

(#106)<br />

Serial Channel Loop<br />

<strong>test</strong> (#229)<br />

On/Off<br />

Board<br />

MAINT (PN Maintenance Circuit Pack)<br />

Recommended Action<br />

MIN ON <strong>test</strong> maintenance r 3<br />

MIN ON <strong>test</strong> maintenance r 3<br />

WRN ON <strong>test</strong> maintenance<br />

MIN ON <strong>test</strong> maintenance r 3<br />

MIN ON <strong>test</strong> maintenance r 3<br />

3329 (e) Any Serial Link Test (#337) MIN<br />

1<br />

WRN<br />

OFF <strong>test</strong> maintenance r 3<br />

3585 (f) Any Serial Link Test (#337) MIN<br />

WRN2 OFF <strong>test</strong> maintenance r 3<br />

1. Major <strong>and</strong> Minor alarms may be downgraded to Warning alarms based on the value used in set options.<br />

2 of 2<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its procedures.<br />

b. Error Type 1, 513, 2561, 2817: a value of 0 indicates that PNC-A (<strong>and</strong> therefore, the<br />

Expansion Interface circuit pack located on PNC-A) was active when this <strong>error</strong> occurred. A<br />

value of 1 indicates that PNC-B (<strong>and</strong> therefore, the Expansion Interface circuit pack located<br />

on PNC-B) was active when this <strong>error</strong> occurred. To clear this problem, make sure the active<br />

PNC is the same as that indicated by the Aux Value.<br />

c. Error Type 769: multiple values can appear in the Aux Data field. There will be other<br />

<strong>error</strong>s in the log if there is a real problem. Use these other <strong>error</strong>s to troubleshoot the<br />

problem.<br />

d. Error Type 1537, 2049: the PN’s Maintenance circuit pack hardware vintage does not<br />

support battery holdover for all carriers. This failure indicates that the cabinet administration<br />

is set for battery holdover for all carriers.<br />