Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 541: Emergency Transfer Query Test (#1532) 1 of 2<br />

Error<br />

Code<br />

1000<br />

2000<br />

1<br />

2<br />

Test<br />

Result<br />

Description <strong>and</strong> recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

The response to a query was not received in the time allowed.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals 1 to 3 times.<br />

FAIL The emergency transfer is set to Manual-Off.<br />

The emergency transfer is set to Manual-On.<br />

1. Enter the status cabinet cab or status health cab<br />

comm<strong>and</strong> to display the status of the emergency transfer select<br />

switch:<br />

● “on” means that emergency transfer was manually activated by<br />

the set emergency-transfer on comm<strong>and</strong>.<br />

● “off” means that emergency transfer was manually deactivated<br />

by the set emergency-transfer off comm<strong>and</strong>.<br />

● “auto+” means that the system has a serious alarm that causes<br />

Communication Manager to activate emergency transfer.<br />

● “auto-” means that emergency transfer is not active <strong>and</strong> is not<br />

being controlled by the set emergency transfer comm<strong>and</strong>.<br />

2. If the status is "on" or "off", enter set emergency auto cab<br />

comm<strong>and</strong> to return control of emergency transfer to Communication<br />

Manager.<br />

16 FAIL Embedded software (firmware) has activated emergency transfer. This is<br />

an internal <strong>error</strong>, since Communication Manager should have set the state<br />

to "Manual-on", "Manual-off", or "auto" at the time the TN2312BP was<br />

initiated.<br />

1. Run <strong>test</strong> maintenance cab to see if communications with the<br />

TN2312BP are up.<br />

2. Reset the TN2312BP circuit pack with reset ipserver.<br />

1688 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />