Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 286: Conference Circuit Test (#7) 5 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1020 ABORT The <strong>test</strong> did not run due to either a previously existing <strong>error</strong> on the<br />

specific port or a more general circuit pack <strong>error</strong>.<br />

1. Examine the Error Log for existing <strong>error</strong>s against this port or the<br />

circuit pack <strong>and</strong> attempt to diagnose <strong>and</strong> resolve the previously<br />

existing <strong>error</strong>.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore.<br />

2000 ABORT Response from the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2053 ABORT At least one of the following <strong>error</strong>s is found on the DS1 circuit pack:<br />

● 1281 – Loss of signal<br />

● 1793 – Blue alarm<br />

● 2049 – Red alarm<br />

● 2305 – Yellow alarm<br />

● 1537 – Hyperactivity<br />

Look for these Error Types in the <strong>error</strong> log, <strong>and</strong> follow the procedures<br />

given in the DS1-BD (DS1 Interface Circuit Pack) or UDS1-BD (UDS1<br />

Interface Circuit Pack) maintenance documentation for the listed Error<br />

Types.<br />

2100 ABORT System resources required to run this <strong>test</strong> are not available.<br />

1. Resolve any TONE-PT (Tone Generator) <strong>error</strong>s.<br />

2. If there are no TONE-PT <strong>error</strong>s in the <strong>error</strong> log, retry the <strong>test</strong> at<br />

1-minute intervals for a maximum of 5 times.<br />