SN-CONF (Switch Node Configuration)<br />

c. Error Type 6000: no neighbor link is administered, but the SNI has one. If the Aux Data is 1,<br />

an EI is connected as a neighbor link. If the Aux Data is 2, an SNI is connected as a<br />

neighbor link.<br />

To resolve Error Type 6000 with Aux Data 1, refer to FAIL code 133 for Configuration Audit<br />

(#759). To resolve Error Type 6000 with Aux Data 2, refer to FAIL code 134 for the<br />

Configuration Audit (#759).<br />

d. Error Type 6001: no neighbor link exists between the SNI <strong>and</strong> its neighbor, but a neighbor<br />

link (that is, fiber link) is administered.<br />

To resolve this <strong>error</strong>, refer to FAIL code 135 for Configuration Audit (#759).<br />

e. Error Type 6002: the physical neighbor type does not match administration. The associated<br />

Aux Data value is the location reported by the neighbor SNI that did not match the fiber link<br />

administration. If the aux data is 1, the type of neighbor administered is an SNI <strong>and</strong> the type<br />

of neighbor connected is an EI. If the aux data is 2, the type neighbor administered is an EI<br />

<strong>and</strong> the type of neighbor connected is an SNI.<br />

To resolve Error Type 6002 with aux data 1, refer to FAIL code 136 for Configuration Audit<br />

(#759). To resolve Error Type 6002 with aux data 2, refer to FAIL code 137 for<br />

Configuration Audit (#759)<br />

f. Error Type 6003: the neighbor location does not match administration. To resolve this <strong>error</strong>,<br />

refer to FAIL code 138 for Configuration Audit (#759).<br />

g. Error Type 6004: a peer link does not exist to another equipped SNI. The Aux Data equals<br />

the slot number of the SNI to which this SNI or SNC does not have a peer link. To resolve<br />

this <strong>error</strong>, refer to the FAIL code for Configuration Audit (#759) corresponding to the Aux<br />

Data on the following table:<br />

Aux Data<br />

(slot no.)<br />

2 102<br />

3 103<br />

4 104<br />

5 105<br />

6 106<br />

7 107<br />

8 108<br />

9 109<br />

13 113<br />

Test 759<br />

FAIL Code<br />

1 of 2<br />

Issue 5 May 2009 845