Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 370: 140AY Chel Sanity Inquiry Test (#222) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description/ Recommendation<br />

2000 ABORT Response to the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals a maximum of 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals a maximum of 5 times.<br />

FAIL The <strong>test</strong> failed. Announcements cot be played back over this port.<br />

1. Reset the circuit pack with reset board location <strong>and</strong> then<br />

run this <strong>test</strong> again. If the <strong>test</strong> continues to fail, replace the circuit<br />

pack (see Warning).<br />

2. If there are recurring alarms on this port caused by this <strong>test</strong><br />

failing, replace the circuit pack even if Step 1 works (see<br />

Warning).<br />

WARNING: Replacing<br />

MTP SAT Chel Local Looparound Test (#228)<br />

This <strong>test</strong> is destructive.<br />

This <strong>test</strong> checks TN775D on-board circuitry associated with the serial link for the management<br />

terminal connection. This <strong>test</strong> will not cause the local terminal login to drop, but any data<br />

displayed on the terminal while the <strong>test</strong> is running will be lost.<br />

The PN’s Maintenance circuit pack has three separate serial interfaces, one for each of the<br />

following:<br />

● Management terminal - <strong>test</strong>ed by Test #228<br />

● Active EI circuit pack - <strong>test</strong>ed by Test #229<br />

● St<strong>and</strong>by EI circuit pack - <strong>test</strong>ed by Test #229<br />

This <strong>test</strong> runs on MAINT (PN Maintenance Circuit Pack).<br />

the circuit pack results in loss of integrated<br />

announcements. Refer to General notes.<br />

PASS Announcements can be played back over this port. User-reported<br />

troubles on this pack should be investigated using other port <strong>and</strong> circuit<br />

pack <strong>test</strong>s. Refer to -BD (Announcement circuit pack) for a description<br />

of the circuit pack <strong>test</strong>s.<br />

1304 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />