Table 359: Data Module Internal Looparound Test (#175) 4 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Data Module Internal Looparound Test (#175)<br />

2314 ABORT Data Module did not respond to downlinked message.<br />

1. Check the wiring of the Data Module under <strong>test</strong>.<br />

2. Verify that the Data Module is powered (power LED on).<br />

3. Make sure the switches are on NORM, OFF (between REM_LP <strong>and</strong><br />

LOC_LP), 9600, <strong>and</strong> ASYN.<br />

4. If the <strong>test</strong> still aborts, replace the Date Module.<br />

5. If the same abort code appears, replace the Digital Line circuit pack<br />

that is connected to the Data Module.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

3004 ABORT This <strong>error</strong> has several causes.<br />

1. This <strong>error</strong> could be caused by the switch setting of the PDM. Verify<br />

that the switch on the PDM is set to the "remote loop" position.<br />

When the remote looparound <strong>test</strong> is completed, return the switch to<br />

the "off" position.<br />

2. This <strong>error</strong> could also result if no data equipment is connected to the<br />

data module. Verify that (a) the data equipment is properly<br />

connected to the data module, (b) that power is available to the data<br />

equipment, <strong>and</strong> that (c) the data equipment is powered on.<br />

3. This <strong>error</strong> could also occur if the baud rate of the data module is set<br />

to 19.2 Kbps since the Network Control circuit pack used by this <strong>test</strong><br />

does not support baud rates greater than 9600 bps. Verify that the<br />

baud rate of the data module is set to 9600 bps or less.<br />

FAIL Data received from remote loopback does not match data sent.<br />

1. Check for faulty wiring.<br />

2. Replace the data module <strong>and</strong> repeat the <strong>test</strong>.<br />

3. If the <strong>test</strong> fails, replace the Digital Line circuit pack associated with<br />

the data module <strong>and</strong> repeat the <strong>test</strong>.<br />

PASS Data Module Looparound <strong>test</strong> passed.<br />

4 of 4<br />