Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Power/Fan Lead Query Test (#1533)<br />

The Power/Fan Query Test sends a request for the state of the power/fan lead (AuxSig) to the<br />

TN2312BP IPSI board in the G650 with an A carrier address. If the lead is on, the <strong>test</strong> fails. If<br />

the lead is off, the <strong>test</strong> passes. This <strong>test</strong> runs on CAB-PFL (Power Fan Lead).<br />

Table 542: Power/Fan Lead Query Test (#1533) 1 of 3<br />

Error<br />

Code<br />

1000<br />

2000<br />

2029<br />

2035<br />

2319<br />

2500<br />

Test<br />

Result<br />

Description <strong>and</strong> recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

The response to a query was not received in the time allowed.<br />

Internal <strong>error</strong>.<br />

The EPN is unavailable or going down.<br />

EPN is out of range.<br />

Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at one-minute intervals up to 3 times.<br />

1 FAIL G650: In a G650 carrier, this indicates a failure in any of the following MOs:<br />

● SER-BUS (Serial Communication Bus)<br />

● POW-SUP (Power Supply)<br />

● CAB-TEMP (Cabinet Temperature)<br />

● PS-RGEN (Power Supply Ring Generator)<br />

Use the diagnostic procedures for those MOs to clear the problem.<br />

1690 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />