Table 91: DS1-BD Error Log Entries 4 of 4<br />

Error Type Aux<br />

Data<br />

2817 Minor Alarm<br />

Inquiry <strong>test</strong> (#143)<br />

3073 to<br />

3160 (s)<br />

3329 to<br />

3345 (t)<br />

Any Slip Alarm Inquiry<br />

<strong>test</strong> (#144)<br />

Any Misframe Alarm<br />

Inquiry <strong>test</strong> (#145)<br />

3840 (u) Any None<br />

3900 (v) Any CPE Loopback<br />

Jack <strong>test</strong> (#1212)<br />

3901(w) Any Far CSU<br />

Loopback <strong>test</strong><br />

(#1213)<br />

3902 (x) Any One-Way Span<br />

<strong>test</strong> (#1214)<br />

3999 (y) Any<br />

Associated Test Alarm<br />

Level<br />

MIN<br />

WRN†<br />

MIN<br />

WRN†<br />

MIN<br />

WRN†<br />

DS1-BD (DS1 Interface Circuit Pack)<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to the <strong>test</strong>’s description <strong>and</strong> follow the recommended procedures.<br />

b. Error Type 1: the circuit pack stopped functioning or is not completely administered. The<br />

alarm is logged approximately 15 minutes after the circuit pack has been removed or 11<br />

minutes after the SAKI <strong>test</strong> (#53) fails.<br />

To be completely administered, a DS1 circuit pack must:<br />

● Have an entry in the circuit plan field in change circuit-packs<br />

● Be administered using add ds1 location<br />

On/Off<br />

Board<br />

Recommended Action<br />

OFF <strong>test</strong> board location<br />

OFF <strong>test</strong> board location r 6<br />

OFF <strong>test</strong> board location r 6<br />

4 of 4<br />

● Be physically inserted in the correct slot<br />

If the circuit pack has an entry in the circuit plan <strong>and</strong> either of the other two conditions are<br />

not met, a MINOR alarm is logged. To resolve the <strong>error</strong>, either:<br />

● Make sure all conditions for administration are met <strong>and</strong> that a functioning DS1 circuit<br />

pack is inserted in the correct slot, or<br />

● Completely remove the DS1-BD from the system:<br />

1. Remove any administered DS1 trunks or access endpoints associated with the<br />

circuit pack from their trunk groups.<br />

Issue 5 May 2009 349