e. Error Type 513: the active SNC determines that there is a problem communicating with the<br />

st<strong>and</strong>by SNC via the connecting serial chel.<br />

If the switch node carrier is administered with duplicate SNCs:<br />

1. If the st<strong>and</strong>by SNC (the one with its yellow LED off) has this <strong>error</strong>, escalate the<br />

problem. (status switch-node also shows the active <strong>and</strong> st<strong>and</strong>by SNCs.)<br />

2. If the system originally had duplicate SNCs <strong>and</strong> the st<strong>and</strong>by SNC was removed <strong>and</strong><br />

never replaced <strong>and</strong> the active SNC has not been reset after the st<strong>and</strong>by SNC was<br />

removed, this <strong>error</strong> will occur.<br />

If you do not intend to replace the SNC:<br />

a. Remove the st<strong>and</strong>by SNC from circuit pack administration using<br />

change circuit-pack.<br />

b. If the problem persists, replace the active SNC circuit pack. Otherwise, insert an<br />

SNC circuit pack.<br />

3. Use display <strong>error</strong>s to check the <strong>error</strong> log. If SNIs in the switch node carrier also<br />

have problems communicating with the active SNC (i.e., <strong>error</strong> code 257 is logged<br />

against SNI-BD), then replace the active SNC.<br />

4. Replace the st<strong>and</strong>by SNC circuit pack.<br />

5. Retry <strong>test</strong> board. Use display <strong>error</strong>s to check the <strong>error</strong> log. If this <strong>error</strong> is still in<br />

the <strong>error</strong> log, replace the active SNC.<br />

If the switch node carrier is administered with only one SNC:<br />

● If step 2 above does not apply, replace the SNC.<br />

f. Error Type 769: the st<strong>and</strong>by SNC determined that there is a problem communicating with<br />

the active SNC through the connecting serial chel.<br />

1. If the active SNC (yellow LED is on) has this <strong>error</strong>, escalate the problem. (The status<br />

switch-node comm<strong>and</strong> also shows the active <strong>and</strong> st<strong>and</strong>by SNCs.)<br />

2. Use display <strong>error</strong>s to check the <strong>error</strong> log. If more than one SNI in the switch node<br />

carrier has problems communicating with the active SNC (that is, Error Type 257 is<br />

logged against SNI-BD), then replace the active SNC.<br />

3. If a single SNI has SNI-BD <strong>error</strong> 257, replace the SNI circuit pack.<br />

4. Replace the st<strong>and</strong>by SNC circuit pack.<br />

5. Retry <strong>test</strong> board. Use display <strong>error</strong>s to check the <strong>error</strong> log. If this <strong>error</strong> is still<br />

in the <strong>error</strong> log, replace the active SNC.<br />

g. Error Type 1025: the firmware detects problems with the various hardware circuit monitors<br />

that verify correct operation of the reference links. Replace the SNC circuit pack.<br />

852 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers