Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

ATM Board Time Of Day Update (#1261)<br />

The ATM circuit pack requires a reference time for SDH/SONET performance monitoring. This<br />

<strong>test</strong> sends the system time to the board to set the time of day. The update synchronizes the<br />

board with the system’s clock. This <strong>test</strong> runs on ATM-EI (Expansion Interface Circuit Pack),<br />

ATM-TRK (Circuit Emulation Service Circuit Pack).<br />

Table 500: ATM Board Time Of Day Update (#1261)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2031 FAIL The attempt to send the downlink message to the circuit pack failed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2500 FAIL Internal operation failed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

PASS The circuit pack was successfully updated with the system time.<br />

1. If status port-network still indicates that this link is down, it is<br />

possible that one or both of the ATM circuit packs have been<br />

busied out.<br />

2. If the link still does not come up, reset one or both ATM circuit<br />

packs on the link.<br />

0 NO<br />

BOARD<br />

See NO BOARD for the repair procedures.<br />

SCOTCH Synchronous Looparound Test (#1275)<br />

This <strong>test</strong> is destructive.<br />

This <strong>test</strong> verifies the circuit in the data path of a C-LAN PPP call or VAL announcement port call.<br />

This <strong>test</strong> fails if the data transmitted on the port does not match the data received in the<br />

looparound mode. Failure of this <strong>test</strong> indicates a port hardware fault on the circuit pack.<br />

This <strong>test</strong> aborts if calls are using the port, or if the PPP or VAL link associated with the port is<br />

connected. To avoid this, first enter busyout data-module extension, or busyout port<br />

location, or busyout link link#, which will cause every call <strong>and</strong> link using the port to be<br />