Communication Manager Maintenance Object Repair Procedures<br />

ANL-16-L (16-Port Analog Line)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

ANL-16-L MIN <strong>test</strong> port location l 16-Port Analog Line<br />

WRN <strong>test</strong> port location<br />

The circuit packs listed below provide 16 analog line ports for single-line voice terminals. The<br />

table below indicates which circuit packs are equipped with lightning protection (for<br />

off-premises, out-of -building stations), <strong>and</strong> which ones support the neon message waiting lamp<br />

feature.<br />

S8700 Series | S8500<br />

16-Port Analog Line Circuit Packs<br />

Circuit Pack Off- Premises Neon<br />

TN468B<br />

TN479<br />

y<br />

TN746 y<br />

TN746B y y<br />

TN2135 y<br />

TN2144 y<br />

TN2149 y<br />

TN2180 y<br />

These circuit packs provide 16 ports for analog voice terminals. The TN746, TN468, <strong>and</strong> TN749<br />

support only single-line, on-premises/in-building, analog voice terminals, <strong>and</strong> not off-premises<br />

stations, since these circuit packs are not equipped with lightning protection. The TN746B,<br />

TN2144, TN2149, <strong>and</strong> TN468B support both on-premises <strong>and</strong> off-premises (that is,<br />

out-of-building) analog voice terminals. The TN468, TN468B, TN479, TN2135, TN2144, <strong>and</strong><br />

TN2149 do NOT support the neon message waiting feature.<br />

No maintenance of the terminal connected to the 16-Port Neon Analog Line circuit pack is<br />

performed, except to determine whether or not the terminal is connected. Failures of the neon<br />

message waiting lamp power <strong>and</strong> the common ringing application circuitry are reported as part<br />