TBRI-BD (ISDN Trunk-Side BRI Circuit Pack)<br />

TBRI-BD (ISDN Trunk-Side BRI Circuit Pack)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

TBRI-BD MIN <strong>test</strong> board location long ISDN Trunk-side<br />

BRI Circuit Pack<br />

The TN2185 ISDN trunk-side BRI circuit pack contains eight, 4-wire ports that interface to the<br />

network at the ISDN S/T reference point over two 64 Kb/s chels (B1 <strong>and</strong> B2) <strong>and</strong> over a 16Kb/s<br />

signaling (D) chel.<br />

The B1 <strong>and</strong> B2 chels can be simultaneously circuit-switched or individually packet-switched.<br />

Only one chel per trunk can be packet-switched due to PPE (Packet Processing Element)<br />

limitations. The D-Chel is either circuit-switched or packet-switched. Packet switching uses the<br />

PPE to combine all D-chels into a single physical chel, which is then routed via the<br />

concentration highway to the NCE (Network Control Element) <strong>and</strong> then to the TDM bus. The<br />

circuit-switched connections have a Mu-law or A-law option for voice <strong>and</strong> operate as 64-kbps<br />

clear data chels. The packet-switched chels support the LAPD protocol <strong>and</strong> conform with the<br />

CCITT Q.920 Recommendations for D-chel signaling.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 254: TBRI-BD Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> board location<br />

1 (b) Any MIN ON<br />

257 (c) 65535 Control Chel Looparound<br />

Test (#52)<br />

513 (d) 4352 -<br />

4357<br />

769 (e) 4358<br />

MIN ON <strong>test</strong> board location r 20<br />

None ON<br />

1025 (f) NPE Audit Test (#50) None ON<br />

1291 (g) 4359 Clear Error Counters (#270) MIN ON<br />

1294 (h) 46088 -<br />

46096<br />

SAKI Sanity <strong>test</strong> (#53) MIN ON See (h)<br />

1537 (i) 46082 MIN ON<br />

1793 (j) 46080 MIN ON<br />