Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

BRI Port Slip Query Test (#1244)<br />

Slips occur when the transmitter <strong>and</strong> receiver are not running at precisely the same clock rate.<br />

The BRI Slip Query Test polls the total number of slips that have occurred on a link.<br />

If the slip count is over the threshold, a MINOR alarm is raised against the circuit pack, leaving<br />

every port of the circuit pack in the in-service state.<br />

TN2185 only: If the TN2185 circuit pack is supplying the system synchronization source, the<br />

MINOR alarm will initiate a synchronization source switch. See TDM-BUS (TDM Bus) <strong>and</strong><br />

SYNC (Port Network Synchronization) for additional information.<br />

This <strong>test</strong> runs on TBRI-PT (ISDN Trunk-Side BRI Port).<br />

Table 493: BRI Port Slip Query Test (#1244) 1 of 2<br />

Error<br />

Code<br />

2000<br />

2012<br />

2100<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

Internal system <strong>error</strong>.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 to 88 FAIL The circuit pack <strong>and</strong> the remote endpoint are not synchronized to the<br />

same clock rate. The Error Code equals the number of slips detected<br />

by the circuit pack since the last Slip Alarm Inquiry <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the circuit pack is a TN2185, enter list measurement<br />

ds1-log location to read the <strong>error</strong> seconds measurement.<br />

3. Verify that both endpoints of the DS1 link are administered<br />

using the same signaling mode, framing mode, <strong>and</strong> line coding.<br />

4. Check the physical connections of DS1 Interface circuit packs<br />

<strong>and</strong> cable.<br />

5. Replace the local DS1 Interface circuit pack <strong>and</strong> repeat the <strong>test</strong>.<br />

6. Contact T1 Network Service to diagnose the remote DS1<br />

endpoint.<br />

PASS No Slips are detected on the circuit pack.<br />