Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 340: Yellow Alarm Inquiry Test (#141) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time. This may<br />

be due to hyperactivity.<br />

1. Enter display <strong>error</strong>s on the SAT.<br />

2. Check for Error Type 1538 for this DS1 board. If Error Type 1538<br />

appears in the <strong>error</strong> log for this board, see Hyperactive DS1/UDS1<br />

Interface Circuit Pack/Media Module for the repair procedures.<br />

Otherwise, retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The DS1/UDS1 interface circuit pack or media module detected a yellow<br />

alarm sent by the remote DS1 endpoint. An out of frame condition<br />

occurred at the DS1 endpoint.<br />

1 FAIL The DS1/UDS1 Interface circuit pack or media module detected a<br />

Remote Multiframe Alarm sent by the remote DS1 endpoint. An<br />

out-of-frame condition occurs on the remote DS1 endpoint.<br />

2 FAIL The DS1/UDS1 Interface circuit pack or media module is reporting a<br />

yellow F5 State alarm. There is a fault in the user-network interface from<br />

the user to the network.<br />

1. If the DS1/UDS1 circuit pack or media module connects to a T1<br />

network facility or to another switch, see T1 Network Facility<br />

Procedures<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

2. If the DS1/UDS1 circuit pack or media module connects to a<br />

line-side terminating device such as a PRI terminal adapter, see<br />

Line-side Terminating Device Procedures<br />

PASS No Yellow alarm or Remote Multiframe Alarm or F5 State Alarm is<br />

received from the remote DS1 endpoint.<br />

See NO BOARD for the repair procedures.<br />