Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 438: FIBER-LK Configuration Audit (#759) 3 of 10<br />

Error<br />

Code<br />

102 -<br />

109,<br />

113 -<br />

120<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The SNI circuit pack cot communicate with the SNI in a different slot.<br />

1. Perform the Fiber link fault isolation procedures described in Chapter<br />

4: General troubleshooting in Maintenance Procedures for <strong>Avaya</strong><br />

Aura Communication Manager, Media Gateways <strong>and</strong> Servers<br />

(03-300432). This should resolve multiple SNI-PEER <strong>error</strong>s.<br />

2. Determine the slot number of the other SNI: Subtract 100 from the<br />

Error Code. For example, if the Error Code is 107, the SNI slot<br />

number is 7. This number is referred to as the "specified SNI slot".<br />

See Table 435: SNI Slot / Error Type to determine the Error Type for<br />

SNI-PEER <strong>error</strong>s for this specified SNI slot. For example, for SNI slot<br />

9, the Error Type is 1793.<br />

3. If the SNI being <strong>test</strong>ed has SNI-PEER <strong>error</strong>s of the Error Type<br />

specified in Step 2, replace the SNI being <strong>test</strong>ed. Replacing an SNI<br />

may be service interrupting. Refer to SNI-BD (SNI Circuit Pack) for<br />

the procedure to replace an SNI. To view SNI-PEER <strong>error</strong>s, enter<br />

display <strong>error</strong>s with category PNC-PEER. Retry the comm<strong>and</strong>.<br />

4. If the SNI being <strong>test</strong>ed still has SNI-PEER <strong>error</strong>s of the specified<br />

Error Type, replace the SNI in the specified SNI slot.<br />

112 FAIL The SNI circuit pack cot communicate with the active SNC.<br />

1. Enter list fiber-link to see a fiber link’s endpoints.<br />

2. Check the <strong>error</strong> log for other SNI circuit packs in the same carrier<br />

with an SNI-BD <strong>error</strong> with Error Type 257. Enter display <strong>error</strong>s<br />

with category PNC to view SNI-BD <strong>error</strong>s. If other SNI circuit packs<br />

in the same switch node carrier have Error 257, replace the active<br />

SNC in this switch node carrier. Replacing an SNC may be service<br />

interrupting. Refer to SNC-BD (Switch Node Clock Circuit Pack) for<br />

the procedure for replacing an SNC.<br />

3. Replace this SNI. Refer to SNI-BD (SNI Circuit Pack) for the<br />

procedure.<br />

4. Replace the active SNC in the same switch node carrier.<br />

1462 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />