Table 328: Ring Generator Query Test (#118) 4 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Ring Generator Query Test (#118)<br />

FAIL Procedure for a single-carrier cabinet system:<br />

There is no ringing voltage in the carrier where the active Tone-Clock<br />

circuit pack resides. Other carriers may or may not have ringing voltage.<br />

1. If this is a duplicated system, determine the active Tone-Clock<br />

circuit pack. Enter set tone-clock location to make the<br />

st<strong>and</strong>by Tone-Clock circuit active, <strong>and</strong> rerun the <strong>test</strong>.<br />

a. If the <strong>test</strong> passes, then the trouble is with the “new” st<strong>and</strong> by<br />

Tone-Clock circuit pack. See TONE-BD (Tone-Clock Circuit<br />

Pack) for details on replacing the st<strong>and</strong>by Tone-Clock circuit<br />

pack. After the circuit pack is replaced, use set tone-clock<br />

location to make this Tone-Clock circuit active, <strong>and</strong> rerun<br />

the <strong>test</strong>.<br />

b. If the <strong>test</strong> fails, proceed with Step 2.<br />

2. Unseat every analog circuit pack in the cabinet that contains the<br />

active Tone-Clock circuit pack, <strong>and</strong> rerun the <strong>test</strong>.<br />

3. If the <strong>test</strong> passes, then the ring generator is healthy <strong>and</strong> one of the<br />

analog circuit packs is defective. Replace the analog circuit packs<br />

one at a time, <strong>and</strong> rerun the <strong>test</strong> to determine which circuit pack is<br />

causing the problem. Replace the defective analog circuit pack.<br />

Rerun the <strong>test</strong>. If the <strong>test</strong> still fails, go to Step 4.<br />

4. Replace the WP-91153 power unit for the affected carrier, <strong>and</strong><br />

rerun the <strong>test</strong>. If the <strong>test</strong> still fails, go to Step 5.<br />

5. The active Tone-Clock may be faulty <strong>and</strong> incorrectly reporting the<br />

level of the ringing voltage. Replace the active Tone-Clock, <strong>and</strong><br />

rerun the <strong>test</strong>. See TONE-BD (Tone-Clock Circuit Pack) for details<br />

on replacing the active Tone-Clock circuit pack. Rerun the <strong>test</strong>.<br />

PASS The analog ringing voltage level is acceptable. For a single-carrier cabinet<br />

stack, ringing voltage is acceptable in the cabinet containing the active<br />

Tone-Clock circuit pack.<br />

4 of 4<br />

Issue 5 May 2009 1213