DIG-IP-S (Digital IP Station)<br />

i. Error Type 2817 tracks failures of the port hyperactivity counter. If a port generates more<br />

than 50 uplink CCMS messages within 10 seconds, the port is taken out-of-service for 30<br />

seconds. Even though the Softphone actually signals over a TCP/IP link, DCP CCMS<br />

messages received over the TCP link are counted as regular CCMS uplinks <strong>and</strong> can cause<br />

the station to be marked as hyperactive.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

Registration Status Inquiry Test (#1372) X X ND<br />

Signaling Path PING Test (#1373) X X ND<br />

Digital Station Lamp Update (#16) X X ND<br />

Digital Station Audits Test (#17) X ND<br />

1. D = Destructive; ND = Nondestructive<br />