Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 487: One-Way Span Test (#1214) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

PASS The One-Way Span <strong>test</strong> has successfully began transmitting a framed<br />

3-in-24 <strong>test</strong> pattern. The <strong>test</strong> will continue to run until <strong>test</strong> ds1-loop<br />

location end-loopback/span-<strong>test</strong> is entered.<br />

1. Enter release board location to release the trunks or ports.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />

Inject Single Bit Error Test (#1215)<br />

This <strong>test</strong> is destructive.<br />

For documentation purposes, the term DS1 applies to the following:<br />

DS1 Interface circuit packs<br />

DS1 Interface media modules<br />

UDS1 circuit packs.<br />

The Inject Single Bit Error <strong>test</strong> causes a single bit <strong>error</strong> to be sent within an active framed<br />

3-in-24 <strong>test</strong> pattern.<br />

The <strong>test</strong> is highly destructive <strong>and</strong> can only be initiated by entering the comm<strong>and</strong><br />

<strong>test</strong> ds1-loop location inject-single-bit-<strong>error</strong>. An attempt to use this<br />

comm<strong>and</strong> is rejected if none of the three long-duration DS1 loopback/span <strong>test</strong>s (CPE<br />

Loopback Jack <strong>test</strong>, Far CSU Loopback <strong>test</strong>, One-Way Span <strong>test</strong>) are active on a ds1 circuit<br />

pack.<br />

Enter busyout board to busy out all trunks or ports on the DS1 Interface circuit pack before<br />

running the Inject Single Bit Error <strong>test</strong>.<br />

Enter list measurements ds1 summary to show the number of bit <strong>error</strong>s detected<br />

(Loopback/Span Test Bit-Error Count field). Injecting this single bit <strong>error</strong> should<br />

increment the bit <strong>error</strong> count of the loopback/span <strong>test</strong> by one.<br />

Enter release board to restore the trunks or ports on the DS1 Interface circuit pact to the<br />

in-service state.<br />

1594 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

3 of 3