UDS1-BD (UDS1 Interface Circuit Pack)<br />

c. Error Type 23: the UDS1-BD circuit pack is not completely administered. To be fully<br />

administered, the UDS1 circuit pack must:<br />

● Have an entry in the circuit plan using change circuit-pack<br />

● Be administered using add ds1 location<br />

● Be physically inserted into the correct slot<br />

A DS1 (UDS1-BD <strong>and</strong> DS1-BD) differs from most circuit packs in that inserting the circuit<br />

pack into the switch is not enough to make the board usable. It must also be administered<br />

with add ds1.<br />

d. Error Type 125: (no Aux Data): an incorrect circuit pack is inserted in the slot where the<br />

USD1 circuit pack is logically administered. To resolve this problem, do one of the following:<br />

● Remove the incorrect circuit pack, <strong>and</strong> insert the correct logically administered circuit<br />

pack.<br />

● Use change circuit-pack to re-administer this slot to match the circuit pack<br />

inserted.<br />

Aux Data 3: the 24-/32-chel option jumper setting on the circuit pack does not match the<br />

option set on the DS1 Circuit Pack administration screen. The circuit pack must be<br />

physically removed to see the setting of the jumper.<br />

e. Error Type 257: associated with the Common Port Circuit Pack Maintenance <strong>test</strong>. See<br />

XXX-BD (Common Port Circuit Pack/Media Module) for details.<br />

f. Error Type 513: the UDS1 Interface circuit pack has detected a transient hardware<br />

problem. The value in the Aux Data field indicates the type of hardware problem:<br />

Aux Data Problem<br />

4352 External RAM failure<br />

4353 Internal RAM failure<br />

4355 Internal ROM failure<br />

If the UDS1 board detects only one of these hardware problems, then the <strong>error</strong> will<br />

disappear when none of these faults are detected for 10 minutes. If the same Aux Data<br />

value is logged more than once in a 24-hour period, the circuit pack should be replaced.<br />

g. Error Type 514: LAN External RAM Error. This <strong>error</strong> occurs when there is a hardware fault<br />

in the external RAM. The RAM is used for message buffering to <strong>and</strong> from the Packet bus.<br />

This <strong>error</strong> should not occur frequently. If it does (10 times within 30 minutes), the circuit<br />

pack should be replaced.<br />

Issue 5 May 2009 1033