Troubleshooting Modem-Pool Symptoms<br />

Certain customer-reported troubles may provide important information for troubleshooting<br />

Modem Pool problems. For example, if the customer tries to make a data call requiring a<br />

Modem Pool conversion resource, <strong>and</strong> the Modem Pool <strong>and</strong> Data Module speeds or other<br />

options do not match, they may receive a CHECK OPTIONS <strong>error</strong> message on the terminal. In<br />

this case, check the Modem Pool administration <strong>and</strong> Data Module option settings. If the Modem<br />

Pool is a Combined type, check also the option settings on the external Modem <strong>and</strong> Data<br />

Module, <strong>and</strong> cabling <strong>and</strong> connections between the Digital Line port, Data Module, Analog Line<br />

port, <strong>and</strong> Modem.<br />

Testing Modem Pools<br />

There are three types of comm<strong>and</strong>s that can be used to <strong>test</strong> Modem Pool circuits: <strong>test</strong> port,<br />

<strong>test</strong> modem-pool #, <strong>and</strong> <strong>test</strong> board. The <strong>test</strong> port comm<strong>and</strong> is generally the first <strong>test</strong><br />

to run after the Error Log is evaluated <strong>and</strong> an entry is found for a Modem Pool port. The <strong>test</strong><br />

modem-pool # comm<strong>and</strong> runs the same <strong>test</strong>s as <strong>test</strong> port short performed on a Modem<br />

Pool port. However, <strong>test</strong> modem-pool # can automatically <strong>test</strong> every port in the Modem Pool<br />

group number specified in #. The <strong>test</strong> board comm<strong>and</strong> performs the same <strong>test</strong>s as <strong>test</strong><br />

port <strong>and</strong> <strong>test</strong> modem-pool # plus additional <strong>test</strong>s for circuits common to the entire circuit<br />

pack.<br />

If the Modem Pool port or group being <strong>test</strong>ed with <strong>test</strong> modem-pool # contains Combined<br />

Modem Pools, the ports on the associated Analog Line circuit pack <strong>and</strong> the TN754 Digital Line<br />

circuit pack are <strong>test</strong>ed as a group. Note, however, that Combined Modem Pools are not <strong>test</strong>ed<br />

<strong>and</strong> the repair information related to Tests #96, 97, 98, <strong>and</strong> 99 is not applicable. The Analog port<br />

of the Combined Modem port is <strong>test</strong>ed with Analog port <strong>test</strong>s, <strong>and</strong> the Digital port of the<br />

Combined Modem port is <strong>test</strong>ed with TDMODULE/PDMODULE <strong>test</strong>s. Therefore, use the repair<br />

procedures outlined in the ANL-LINE, ANL-16-L, ANL-NE-L, <strong>and</strong> TDMODULE/PDMODULE<br />

Maintenance documentation when interpreting the results of the execution of <strong>test</strong><br />

modem-pool # on Combined Modem Pools.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 193: MODEM-PT Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> port location<br />

670 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />