Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 510: ATM Crosstalk Test (#1298) 2 of 3<br />

Error<br />

Code<br />

1394 ABORT The ATM-EI board is out of service <strong>and</strong> the <strong>test</strong> cot be run.<br />

1. Run Test #241. If it does not pass, see repair procedures for<br />

Expansion Interface 2-Way Transmission Test (#241).<br />

1395 ABORT This <strong>test</strong> cot be run on an ATM-EI circuit pack if it is part of the B-side<br />

PNC <strong>and</strong> duplicated PNC is not enabled.<br />

1. If this <strong>test</strong> needs to run on this ATM-EI circuit pack, enable PNC<br />

duplication with change system-parameters<br />

duplication.<br />

2. Prevent the system from doing a PNC interchange with<br />

set PNC lock.<br />

3. Repeat this <strong>test</strong>.<br />

1407 ABORT This <strong>test</strong> cot be run on an ATM-EI board that is on the active PNC<br />

because it cot be busied out. This <strong>error</strong> code indicates that PNC<br />

duplication is enabled.<br />

1. Attempt to perform a PNC interchange with<br />

reset pnc interchange.<br />

2. If the PNC interchange is successful, busyout the original<br />

ATM-Expansion Interface circuit pack with busyout board<br />

location (address of the original ATM-EI board).<br />

3. Retry the comm<strong>and</strong>.<br />

1962<br />

2000<br />

2100<br />

2302<br />

2500<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Every TALKER DSP is busy (an unlikely event).<br />

Response to the <strong>test</strong> was not received within the allowed time.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

Inconsistent uplink message from the ATM board.<br />

Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2752 ABORT The circuit pack in this location is not a TN2305 or TN2306.<br />

1–8 FAIL The board is writing to unauthorized TDM time slots. The <strong>error</strong> code<br />

indicates the number of faulted TALKER DSPs.<br />

1. Retry the comm<strong>and</strong> up to 3 times.<br />

2. If the failure persists, replace the circuit pack.<br />

1636 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 3